Linear milk IR calibration sets – medium
Ensure international equivalence with our linear milk IR calibration sets – medium concentration – for mid-infrared milk analyzers
Secure and scheduled shipment of linear milk IR calibration sets - medium concentration
Our linear milk IR calibration sets – medium concentration – are shipped monthly according to a predefined schedule. Each shipment is prepared in isothermal packaging with ice packs to maintain the cold chain and ensure optimal sample preservation. A sealed water bottle is included to monitor temperature stability upon delivery. All shipments are sent via express carrier for rapid and secure transport.
Optimizing milk analyzer performance with our linear milk IR calibration sets - medium concentration
Infrared calibration sets for milk analysis are essential tools for laboratories and dairy processors aiming to ensure accurate and standardized measurement of key milk components. In particular, fat, protein, and lactose concentrations are critical parameters for routine milk quality control and dairy product formulation.
To ensure the accuracy and standardization of milk measurements across instruments and laboratories, mid-infrared analyzers like the DairySpec FT and FTS require regular calibration with reliable reference samples. That’s why Bentley Instruments has developed a dedicated range of linear milk IR calibration sets — carefully designed mid-infrared SRMs (Standard Reference Materials) to optimize the performance and consistency of milk analyzer calibration.
Each calibration set is carefully formulated to include a representative range of fat, protein, and lactose concentrations, making it ideal for routine performance monitoring of infrared milk analyzers.
Linear milk IR calibration sets - medium concentration - SRMs for consistent and accurate mid-infrared calibration
Bentley Instruments’ linear milk IR calibration sets – medium concentration – are composed of 14 raw cow milk samples (100 mL each), carefully selected to cover a representative fat concentration range of 1.0 to 5.0 g/100g. This calibration set is ideal for verifying analyzer linearity and ensuring reliable performance in routine milk composition analysis.
These mid-infrared calibration standards are store at cold positive and contain a stabilizer to preserve sample integrity over time.
Specifically validated for major components analysis in milk, these calibration sets provide optimal control of mid-infrared analyzers such as the DairySpec FT and FTS. They ensure long-term stability, enhanced analytical accuracy, and early detection of instrument drift.
The reference values for each calibration sample are established using the following reference methods:
- Roese-Gottlieb method for fat content
- Kjeldhal method for true protein content
- Kjeldahl method for crude protein content
- HPLC method for lactose
Secure and scheduled shipment of linear milk IR calibration sets - medium concentration
Casein
Fatty acids profile
FPD
Urea
Fill out this form to receive your linear milk IR calibration set(s) – medium concentration – quotation
BENTLEY INSTRUMENTS EU
ZA Brunehaut 840 rue Curie
62161 Maroeuil - France
+33 (0)2 85 52 90 73
Fax : +33 (0)3 20 09 87 12
info@bentleyinstruments.eu
BENTLEY INSTRUMENTS INC.
4004 Peavey Rd Chaska
Minnesota 55318 - USA
+1 952 448 7600
+1 952 368 3355
info@bentleyinstruments.com





