BactoCount IBC

ACCURATE AND RELIABLE ENUMERATION OF INDIVIDUAL BACTERIA IN REAL TIME.
RAPID ANALYSIS OF RAW MILK HYGIENIC QUALITY.
5

Optimal valorisation of the raw milk hygienic quality

The BactoCount IBC is a fully automatic instrument that uses flow cytometry for the fast and extremely reliable enumeration of individual bacteria in raw milk. Certified according to ISO 16140 standard as an alternative method to the reference method (ISO 4833), it provides real-time precision analysis.

Capable of analyzing 50, 100 or 150 samples/hour, the BactoCount IBC effectively meets the needs of dairy laboratories of all sizes.

The BactoCount IBC is fully standardized by conforming to ISO 9001 standards and using our international total flora proficiency testing, accredited to ISO 17043, as well as our freeze-dried IBC and SCC SRM (Secondary Reference Materials).
5

Technical Specifications*

Type of raw milk Cow, sheep, goat, buffalo, …
Carryover ≤ 1% (typically ≤ 0.5%)
Total Flora Certified as an alternative method to the reference method (ISO 4833)
2 – 10,000 kIBC/mL
Repeatability & Reproducibility Range (kIBC/mL)
10 – 50
51 – 100
101 – 300
> 300
Specifications
Sr ≤ 0,07 log
Sr ≤ 0,06 log
Sr ≤ 0,05 log
Sr ≤ 0,03 log
S≤ 0,14 log
S≤ 0,12 log
S≤ 0,10 log
S≤ 0,06 log
Accuracy Sy,x ≤ 0,3 log (ISO 4833 et AOAC 986.33)
Cow: Sy, x = 0.167 (AIA)
Sheep: Sy, x = 0.245 (AIA)
Buffalo: Sy, x = 0.201 (AIA)
Additional technical specifications
Work factor (undiluted) 100 – 200
Speed 50 samples/hour
100 samples/hour
150 samples/hour
Voltage 115/220 V | 50/60 Hz
Dimensions (WxHxD) 152.4 x 121.9 x 61.0 cm
Weight 115.0 kg
Connected to the local database and accessible remotely

*Specifications subject to change without notice.

Technical Specifications*

Type of raw milk Cow, sheep, goat, buffalo, …
Carryover ≤ 1% (typically ≤ 0.5%)
Total Flora Certified as an alternative method to the reference method (ISO 4833)
2 – 10,000 kIBC/mL
Repeatability & Reproducibility Range (kIBC/mL)
10 – 50
51 – 100
101 – 300
> 300
Specifications
Sr ≤ 0,07 log
Sr ≤ 0,06 log
Sr ≤ 0,05 log
Sr ≤ 0,03 log
S≤ 0,14 log
S≤ 0,12 log
S≤ 0,10 log
S≤ 0,06 log
Accuracy Sy,x ≤ 0,3 log (ISO 4833 et AOAC 986.33)
Cow: Sy, x = 0.167 (AIA)
Sheep: Sy, x = 0.245 (AIA)
Buffalo: Sy, x = 0.201 (AIA)
Additional technical specifications
Work factor (undiluted) 100 – 200
Speed 50 samples/hour
100 samples/hour
150 samples/hour
Voltage 115/220 V | 50/60 Hz
Dimensions (WxHxD) 152.4 x 121.9 x 61.0 cm
Weight 115.0 kg
Connected to the local database and accessible remotely

*Specifications subject to change without notice.

The BactoCount IBC is fully standardized by conforming to ISO 9001 standards and using our international total flora proficiency testing, accredited to ISO 17043, as well as our freeze-dried IBC and SCC SRM (Secondary Reference Materials).
Compatible with the new ILAS 4000 for the full automation and standardization of the analytical chain.
5

MAINTENANCE & SUPPORT

Customer service has always been a priority for Bentley Instruments. We guarantee our customers prompt assistance for optimum productivity.

In order to guarantee the highest level of productivity, our team of technicians takes care of installation, training and diagnostics remotely and locally.

The FreshDesk platform is available by registering and gives you access to our e-service platform: e-ticket service to ask our engineers about your problems, technical databases (equipment history, technical notes, manuals...), diagnostic tools (problem/solution), worldwide network of production engineers and after-sales service for a quick and interactive assistance at your disposal at any time.